Sorry for the late reply. Starting from a specific connector sounds
as much as possible. We have already seen some variation of source
Binlog, etc. So it would be good if we can reuse some base abstraction in
> Thanks, Thomas!
>
> @Becket and @Nicholas - would you be ok with that approach?
>
>
> On Thu, Apr 15, 2021 at 6:30 PM Thomas Weise <
[hidden email]> wrote:
>
> > Hi Stephan,
> >
> > Thanks for the feedback!
> >
> > I agree with the approach of starting with a simple implementation
> > that can address a well understood, significant portion of use cases.
> >
> > I'm planning to continue work on the prototype that I had shared.
> > There is production level usage waiting for it fairly soon. I expect
> > to open a PR in the coming weeks.
> >
> > Thomas
> >
> >
> >
> >
> >
> > On Tue, Apr 13, 2021 at 12:15 PM Stephan Ewen <
[hidden email]> wrote:
> > >
> > > Thanks all for this discussion. Looks like there are lots of ideas and
> > > folks that are eager to do things, so let's see how we can get this
> > moving.
> > >
> > > My take on this is the following:
> > >
> > > There will probably not be one Hybrid source, but possibly multiple
> ones,
> > > because of different strategies/requirements.
> > > - One may be very simple, with switching points known up-front.
> Would
> > > be good to have this in a very simple implementation.
> > > - There may be one where the switch is dynamic and the readers need
> > to
> > > report back where they left off.
> > > - There may be one that switches back and forth multiple times
> > during a
> > > job, for example Kakfa going to DFS whenever it falls behind retention,
> > in
> > > order to catch up again.
> > >
> > > This also seems hard to "design on paper"; I expect there are nuances
> in
> > a
> > > production setup that affect some details of the design. So I'd feel
> most
> > > comfortable in adding a variant of the hybrid source to Flink that has
> > been
> > > used already in a real use case (not necessarily in production, but
> maybe
> > > in a testing/staging environment, so it seems to meet all
> requirements).
> > >
> > >
> > > What do you think about the following approach?
> > > - If there is a tested PoC, let's try to get it contributed to Flink
> > > without trying to make it much more general.
> > > - When we see similar but a bit different requirements for another
> > hybrid
> > > source, then let's try to evolve the contributed one.
> > > - If we see new requirements that are so different that they don't
> fit
> > > well with the existing hybrid source, then let us look at building a
> > second
> > > hybrid source for those requirements.
> > >
> > > We need to make connector contributions in general more easy, and I
> think
> > > it is not a bad thing to end up with different approaches and see how
> > these
> > > play out against each other when being used by users. For example
> > switching
> > > with known boundaries, dynamic switching, back-and-forth-switching,
> etc.
> > > (I know some committers are planning to do some work on making
> > > connector contributions easier, with standardized testing frameworks,
> > > decoupled CI, etc.)
> > >
> > > Best,
> > > Stephan
> > >
> > >
> > > On Thu, Mar 25, 2021 at 4:41 AM Thomas Weise <
[hidden email]> wrote:
> > >
> > > > Hi,
> > > >
> > > > As mentioned in my previous email, I had been working on a prototype
> > for
> > > > the hybrid source.
> > > >
> > > > You can find it at
https://github.com/tweise/flink/pull/1> > > >
> > > > It contains:
> > > > * Switching with configurable chain of sources
> > > > * Fixed or dynamic start positions
> > > > * Test with MockSource and FileSource
> > > >
> > > > The purpose of the above PR is to gather feedback and help drive
> > consensus
> > > > on the FLIP.
> > > >
> > > > * How to support a dynamic start position within the source chain?
> > > >
> > > > Relevant in those (few?) cases where start positions are not known
> > upfront.
> > > > You can find an example of what that might look like in the tests:
> > > >
> > > >
> > > >
> >
>
https://github.com/tweise/flink/pull/1/files#diff-8eda4e21a8a53b70c46d30ceecfbfd8ffdb11c14580ca048fa4210564f63ada3R62> > > >
> > > >
> >
>
https://github.com/tweise/flink/pull/1/files#diff-3a5658515bb213f9a66db88d45a85971d8c68f64cdc52807622acf27fa703255R132> > > >
> > > > When switching, the enumerator of the previous source needs to
> > > > supply information about consumed splits that allows to set the start
> > > > position for the next source. That could be something like the last
> > > > processed file, timestamp, etc. (Currently StaticFileSplitEnumerator
> > > > doesn't track finished splits.)
> > > >
> > > > See previous discussion regarding start/end position. The prototype
> > shows
> > > > the use of checkpoint state with converter function.
> > > >
> > > > * Should readers be deployed dynamically?
> > > >
> > > > The prototype assumes a static source chain that is fixed at job
> > submission
> > > > time. Conceivably there could be use cases that require more
> > flexibility.
> > > > Such as switching one KafkaSource for another. A step in that
> direction
> > > > would be to deploy the actual readers dynamically, at the time of
> > switching
> > > > source.
> > > >
> > > > Looking forward to feedback and suggestions for next steps!
> > > >
> > > > Thomas
> > > >
> > > > On Sun, Mar 14, 2021 at 11:17 AM Thomas Weise <
[hidden email]>
> wrote:
> > > >
> > > > > Hi Nicholas,
> > > > >
> > > > > Thanks for the reply. I had implemented a small PoC. It switches a
> > > > > configurable sequence of sources with predefined bounds. I'm using
> > the
> > > > > unmodified MockSource for illustration. It does not require a
> > > > "Switchable"
> > > > > interface. I looked at the code you shared and the delegation and
> > > > signaling
> > > > > works quite similar. That's a good validation.
> > > > >
> > > > > Hi Kezhu,
> > > > >
> > > > > Thanks for bringing the more detailed discussion regarding the
> > start/end
> > > > > position. I think in most cases the start and end positions will be
> > known
> > > > > when the job is submitted. If we take a File -> Kafka source chain
> as
> > > > > example, there would most likely be a timestamp at which we want to
> > > > > transition from files to reading from Kafka. So we would either set
> > the
> > > > > start position for Kafka based on that timestamp or provide the
> > offsets
> > > > > directly. (Note that I'm skipping a few related nuances here. In
> > order to
> > > > > achieve an exact switch without duplication or gap, we may also
> need
> > some
> > > > > overlap and filtering, but that's a separate issue.)
> > > > >
> > > > > The point is that the start positions can be configured by the
> user,
> > > > there
> > > > > is no need to transfer any information from one source to another
> as
> > part
> > > > > of switching.
> > > > >
> > > > > It gets more complicated if we want to achieve a dynamic switch
> > where the
> > > > > transition timestamp isn't known when the job starts. For example,
> > > > consider
> > > > > a bootstrap scenario where the time taken to process historic data
> > > > exceeds
> > > > > the Kafka retention. Here, we would need to dynamically resolve the
> > Kafka
> > > > > start position based on where the file readers left off, when the
> > > > switching
> > > > > occurs. The file source enumerator would determine at runtime when
> > it is
> > > > > done handing splits to its readers, maybe when the max file
> timestamp
> > > > > reaches (processing time - X). This information needs to be
> > transferred
> > > > to
> > > > > the Kafka source.
> > > > >
> > > > > The timestamp would need to be derived from the file enumerator
> > state,
> > > > > either by looking at the last splits or explicitly. The natural way
> > to do
> > > > > that is to introspect the enumerator state which gets checkpointed.
> > Any
> > > > > other form of "end position" via a special interface would need to
> be
> > > > > derived in the same manner.
> > > > >
> > > > > The converter that will be provided by the user would look at the
> > file
> > > > > enumerator state, derive the timestamp and then supply the "start
> > > > position"
> > > > > to the Kafka source. The Kafka source was created when the job
> > started.
> > > > It
> > > > > needs to be augmented with the new start position. That can be
> > achieved
> > > > via
> > > > > a special enumerator interface like
> > > > SwitchableSplitEnumerator#setStartState
> > > > > or by using restoreEnumerator with the checkpoint state constructed
> > by
> > > > the
> > > > > converter function. I'm leaning towards the latter as long as there
> > is a
> > > > > convenient way to construct the state from a position (like
> > > > > enumStateForTimestamp). The converter would map one enum state to
> > another
> > > > > and can be made very simple by providing a few utility functions
> > instead
> > > > of
> > > > > mandating a new interface that enumerators need to implement to
> > become
> > > > > switchable.
> > > > >
> > > > > Again, a converter is only required when sources need to be
> switched
> > > > based
> > > > > on positions not known at graph construction time.
> > > > >
> > > > > I'm planning to add such deferred switching to the PoC for
> > illustration
> > > > > and will share the experiment when that's done.
> > > > >
> > > > > Cheers,
> > > > > Thomas
> > > > >
> > > > >
> > > > > On Mon, Mar 8, 2021 at 1:46 AM Nicholas Jiang <
[hidden email]
> >
> > > > wrote:
> > > > >
> > > > >> Hi Kezhu,
> > > > >>
> > > > >> Thanks for your detailed points for the Hybrid Source. I follow
> your
> > > > >> opinions and make a corresponding explanation as follows:
> > > > >>
> > > > >> 1.Would the Hybrid Source be possible to use this feature to
> > > > switch/chain
> > > > >> multiple homogeneous sources?
> > > > >>
> > > > >> "HybridSource" supports to switch/chain multiple homogeneous
> > sources,
> > > > >> which
> > > > >> have the respective implementation for "SwitchableSource" and
> > > > >> "SwitchableSplitEnumerator". "HybridSource" doesn't limit whether
> > the
> > > > >> Sources consisted is homogeneous. From the user's perspective,
> User
> > only
> > > > >> adds the "SwitchableSource" into "HybridSource" and leaves the
> > smooth
> > > > >> migration operation to "HybridSource".
> > > > >>
> > > > >> 2."setStartState" is actually a reposition operation for next
> > source to
> > > > >> start in job runtime?
> > > > >>
> > > > >> IMO, "setStartState" is used to determine the initial position of
> > the
> > > > new
> > > > >> source for smooth migration, not reposition operation. More
> > importantly,
> > > > >> the
> > > > >> "State" mentioned here refers to the start and end positions of
> > reading
> > > > >> source.
> > > > >>
> > > > >> 3.This conversion should be implementation detail of next source,
> > not
> > > > >> converter function in my opinion?
> > > > >>
> > > > >> The state conversion is of course an implementation detail and
> > included
> > > > in
> > > > >> the switching mechanism, that should provide users with the
> > conversion
> > > > >> interface for conversion, which is defined in converter function.
> > What's
> > > > >> more, when users has already implemented "SwitchableSource" and
> > added to
> > > > >> the
> > > > >> Hybrid Source, the users don't need to implement the
> > "SwitchableSource"
> > > > >> for
> > > > >> the different conversion. From the user's perspective, users could
> > > > define
> > > > >> the different converter functions and create the
> "SwitchableSource"
> > for
> > > > >> the
> > > > >> addition of "HybridSource", no need to implement a Source for the
> > > > >> converter
> > > > >> function.
> > > > >>
> > > > >> 4.No configurable start-position. In this situation combination of
> > above
> > > > >> three joints is a nop, and
> > > > >> "HybridSource" is a chain of start-position pre-configured
> sources?
> > > > >>
> > > > >> Indeed there is no configurable start-position, and this
> > configuration
> > > > >> could
> > > > >> be involved in the feature. Users could use
> > > > >> "SwitchableSplitEnumerator#setStartState" interface or the
> > configuration
> > > > >> parameters to configure start-position.
> > > > >>
> > > > >> 5.I am wonder whether end-position is a must and how it could be
> > useful
> > > > >> for
> > > > >> end users in a generic-enough source?
> > > > >>
> > > > >> "getEndState" interface is used for the smooth migration scenario,
> > which
> > > > >> could return null value if it is not needed. In the Hybrid Source
> > > > >> mechanism,
> > > > >> this interface is required for the switching between the sources
> > > > >> consisted,
> > > > >> otherwise there is no any way to get end-position of upstream
> > source. In
> > > > >> summary, Hybrid Source needs to be able to set the start position
> > and
> > > > get
> > > > >> the end position of each Source, otherwise there is no use to
> build
> > > > Hybrid
> > > > >> Source.
> > > > >>
> > > > >> 6.Is it possible for converter function to do blocking operations?
> > How
> > > > to
> > > > >> respond to checkpoint request when switching split enumerators
> cross
> > > > >> sources? Does end-position or start-position need to be stored in
> > > > >> checkpoint
> > > > >> state or not?
> > > > >>
> > > > >> The converter function only simply converts the state of upstream
> > source
> > > > >> to
> > > > >> the state of downstream source, not blocking operations. The way
> to
> > > > >> respond
> > > > >> the checkpoint request when switching split enumerators cross
> > sources is
> > > > >> send the corresponding "SourceEvent" to coordination. The
> > end-position
> > > > or
> > > > >> start-position don't need to be stored in checkpoint state, only
> > > > >> implements
> > > > >> the "getEndState" interface for end-position.
> > > > >>
> > > > >> Best,
> > > > >> Nicholas Jiang
> > > > >>
> > > > >>
> > > > >>
> > > > >> --
> > > > >> Sent from:
> > > > >>
http://apache-flink-mailing-list-archive.1008284.n3.nabble.com/> > > > >>
> > > > >
> > > >
> >
>