Leonard Xu created FLINK-20405:
----------------------------------
Summary: The LAG function in over window is not implements correctly
Key: FLINK-20405
URL:
https://issues.apache.org/jira/browse/FLINK-20405 Project: Flink
Issue Type: Bug
Components: Table SQL / Runtime
Affects Versions: 1.12.0
Reporter: Leonard Xu
For LAG(input, offset, default) function in over window, it always return current row's input no matter how the offset is set.
After see the codegen code of the function, I think the implementation is not correct and need to correct.
{code:java}
// the offset and default value is never used
public UnboundedOverAggregateHelper$24(java.lang.Object[] references) throws Exception { constant$14 = ((int) 1); constant$14isNull = false; constant$15 = ((org.apache.flink.table.data.binary.BinaryStringData) str$13); constant$15isNull = false; typeSerializer$19 = (((org.apache.flink.table.runtime.typeutils.StringDataSerializer) references[0])); }
public void accumulate(org.apache.flink.table.data.RowData accInput) throws Exception { org.apache.flink.table.data.binary.BinaryStringData field$21; boolean isNull$21; org.apache.flink.table.data.binary.BinaryStringData field$22; isNull$21 = accInput.isNullAt(2); field$21 = org.apache.flink.table.data.binary.BinaryStringData.EMPTY_UTF8; if (!isNull$21) { field$21 = ((org.apache.flink.table.data.binary.BinaryStringData) accInput.getString(2)); } field$22 = field$21; if (!isNull$21) { field$22 = (org.apache.flink.table.data.binary.BinaryStringData) (typeSerializer$19.copy(field$22)); } if (agg0_leadlag != field$22) { agg0_leadlag = ((org.apache.flink.table.data.binary.BinaryStringData) typeSerializer$19.copy(field$22)); } ; agg0_leadlagIsNull = isNull$21; }
{code}
The question comes from user mail list[1]
[1]
http://apache-flink-user-mailing-list-archive.2336050.n4.nabble.com/FlinkSQL-kafka-gt-dedup-gt-kafka-td39335.html--