Stephan Ewen created FLINK-1765:
-----------------------------------
Summary: Reducer grouping is skippted when parallelism is one
Key: FLINK-1765
URL:
https://issues.apache.org/jira/browse/FLINK-1765 Project: Flink
Issue Type: Bug
Components: Streaming
Affects Versions: 0.9
Reporter: Stephan Ewen
Fix For: 0.9
This program (not the parallelism) incorrectly runs a non grouped reduce and fails with a NullPointerException.
{code}
StreamExecutionEnvironment env = ...
env.setDegreeOfParallelism(1);
DataStream<String> stream = env.addSource(...);
stream
.filter(...)
.map(...)
.groupBy("someField")
.reduce(new ReduceFunction() {...} )
.addSink(...);
env.execute();
{code}
--
This message was sent by Atlassian JIRA
(v6.3.4#6332)