lining created FLINK-14712:
------------------------------
Summary: Add NetWork metric for IOMetricsInfo
Key: FLINK-14712
URL:
https://issues.apache.org/jira/browse/FLINK-14712 Project: Flink
Issue Type: Bug
Components: Runtime / Metrics, Runtime / Network, Runtime / REST
Reporter: lining
Attachments: image-2019-11-12-14-30-16-130.png
h4. (1) The current monitor is heavy-weight.
* Backpressure monitoring works by repeatedly taking stack trace samples of your running tasks.
h4. (2) It is difficult to find out which vertex is the source of backpressure.
* User need to know current and upstream's network metric to judge current whether is the source of backpressure. Now user has to record relevant information.
h3. Proposed Changes
Update IOMetricsInfo add outPoolUsage, inputExclusiveBuffersUsage, inputFloatingBuffersUsage:
public final class IOMetricsInfo { private final float outPoolUsage; private final float inputExclusiveBuffersUsage; private final float inputFloatingBuffersUsage;}
JobDetailsInfo.JobVertexDetailsInfo merge use Math.max.(ps: outPoolUsage is from upstream)、
According to !image-2019-11-12-14-30-16-130.png!
--
This message was sent by Atlassian Jira
(v8.3.4#803005)