Andrew Prudhomme created FLINK-11915:
----------------------------------------
Summary: DataInputViewStream skip returns wrong value
Key: FLINK-11915
URL:
https://issues.apache.org/jira/browse/FLINK-11915 Project: Flink
Issue Type: Bug
Reporter: Andrew Prudhomme
The flink-core:org.apache.flink.api.java.typeutils.runtime.DataInputViewStream overrides the InputSteam skip function. This function should be returning the actual number of bytes skipped, but there is a bug which makes it return a lower value.
The fix should be something simple like:
{code:java}
- return n - counter - inputView.skipBytes((int) counter);
+ return n - (counter - inputView.skipBytes((int) counter));
{code}
For context, I ran into this when trying to decode an Avro record where the writer schema had fields not present in the reader schema. The decoder would attempt to skip the unneeded data in the stream, but would throw an EOFException because the return value was wrong.
--
This message was sent by Atlassian JIRA
(v7.6.3#76005)