Shimin Yang created FLINK-11084:
-----------------------------------
Summary: Incorrect ouput after two successive split and select
Key: FLINK-11084
URL:
https://issues.apache.org/jira/browse/FLINK-11084 Project: Flink
Issue Type: Bug
Components: Streaming
Reporter: Shimin Yang
Assignee: Shimin Yang
Fix For: 1.5.6, 1.6.3, 1.8.0, 1.7.1
The second OutputSelector of two successive split and select are actually not rely on the first one. They are in the same array of OutputSelector in DirectedOutput.
For example.
outputSelector1 => \{“name1” or ”name2“}
outputSelector2 => \{”name3“ or “name4”}
resultStream = dataStream.split(outputSelector1).select("name2").split(outputSelector2).select("name3")
expectedResult for input \{StreamRecord1}:
outputSelector1 => \{”name1“}
outputSelector2 => \{”name3“}
resultStream => {}
actualResult:
resultStream => \{StreamRecord1}
--
This message was sent by Atlassian JIRA